radiant ceiling heat 1970s
Some of the folks who say radiant ceiling heat is horrible don't have a clue! I am not promoting heating a house with radiant ceiling panels, so don't set up that straw man just to knock it down. This type of heating has the same advantages of other forms of electric resistance heat, including electric resistance baseboard, electric mats under your tile floor, and electric resistance space heaters. I would get another opinion from a licensed electrician. Broan 157 1250W Electric Radiant Ceiling Heater Surface Mount . Radiant ceiling heat has been available in some form for over 50 years. My mom has electric ceiling heat and she has a digital T-stat. Actually, electric radiant heat has all of the advantages of radiant heat and none of the drawbacks of convection electric heat as stated above. Or go with something totally different like a mini split? All of the heat was in the ceiling. There was 1260 watts of heating installed in this area, along with 576 watts of fluorescent tubes. Alas, I've gone beyond the point of answering the Original Poster's question, and I don't wish to derail his thread. Energy savings are still possible through zoning of in-floor systems, as would be true of other systems that permit zoning (e.g. In a well insulated home with the proper number of panels per the home heat loss . We replaced it with hardibacker but after priming and painting still doesn't look good any suggestions how to refinish? First of all, your lectures about mean radiant temperatures and comfort are condescending. "Studies conducted by the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) indicate that with radiant heating systems people can be comfortable at temperatures 6F to 8F lower than with convective systems. The mats dont get any hotter than the hottest parts of the lighting fixtures. A feeder line runs from the other side of the thermostat to the single wire heating grid sandwiched between two layers of drywall ceiling, then back to the second hot wire to complete the circuit. Does that sound realistic? Here are two super-useful articles (10 to 20 minute read each): Its facts and opinions are those of BobVila.com. Example: Take two houses in the winter both heated to 68 degrees. Good luck to everyone and stay warm!! The best way for one to reduce their energy consumption is to use electric radiant ceiling heat. Trying to find out what kind of wire I should use to repair it before burying it in mud again. Your comments regularly confuse the concept of energy savings with the concept of dollar savings. . https://radiantcooling.com/how-radiant-ceiling-works/. Billy, See: Ceiling heat from 1964 in Maryland. The hardware of this device is mounted over the head making it very practical for homeowner living in small houses. worst heating ever and super inefficient. It is basically a thin wire with a thick insulation and a fiberglass type sheath that slides over the splice, with a peice of heat shrink on each end. posted Sunday Jan 17, 2016:Well, nice to find this little group/conversation. When applied to the sizing of a radiant system, conventional heat-loss analysis often includes a reduction in design temperature from 70F to 65F and a 10% to 25% reduction in building air infiltration, exfiltration, stratification and glass heat loss. Thank you Mr. Kilbride for your informed comments. These differences cause some owners to be dissatisfied with the overall operation of the system. radient ceiling heat in all the rooms. https://www.calorique.com/pro-series-heating/radiant-ceiling-heat/, Thanks Sandy, sounds awesome that it's 3D printed. Last Post 03 Feb 2009 06:25 PM by walltech. This article has been brought to you by Warmboard. Perhaps better than a carpeted radiant floor hot rod capabilities with low-temperature and low-intensity energy sources such as solar systems and heat pumps (Kilkis et al., 1995) (4) while maintaining acceptable thermal comfort (Imanari et al., Otherwise we keep it on 55 degrees to keep the house from getting too cold when we are at work. Of course people feel uncomfortable when surrounded by cold surfaces, which is why I have been preaching the virtues of triple-glazed windows and superinsulated walls in cold climates for many years. JavaScript is disabled. ( but i don't like spiders and dirt in the house :p ). The $500 is based on 7 cents per kwh. Turn the breaker off before fooling with anything! Of course the person standing next to the radiant panel is more comfortable, which means you CANNOT just compare air temperatures and do BTU calculations based on electric and gas. Finding a few cracked ceilings and staining near the walls as expected. We had zan oil stove downstairs that helped keep electricity cost down. If we make no adjustments I think we will make it to end of February. The heaters have a very low surface temperature and gently warm the space. I am seriously considering ceiling hydronic radiant heat for a project I am working on, and I came across this sometime heated GBA thread while researching the topic. - Answered by a verified HVAC Technician. Forced air heating and cooling is integrated and common in homes with existing ductwork. . 1990; Ling and Deffenbaugh, 1990) because the radiant heat from the heater falls directly (or indirectly through surfaces) on the occupants thus producing more comfortable conditions. They had told her to feel free to use the electric ceiling heat (very similar to own nearby home built same era, 1963 - 68-ish, same kitchen cabinet hardware, same foyer slate. probably same builder), although they have not used it in most of the rooms in the six years they've owned the house because they have a really great cast-iron fireplace insert. It is not that simple minded. My condo was built in the 80's and apparently radiant ceiling heat was all the rage. It appears the wires are embedded in the drywall. I shouldn't complain about getting older since many don't get the privilege but my DIY days are over. We like it very much. In an attempt to repair it I found 3 cut wires. The home isn't "super insulated" - R50 ceiling, R21 walls and no insulation under the slab (except for one room, the entire house is on the one level. So if youre sleeping in a second-floor bedroom, you no longer need to cover the cost necessary to keep the unoccupied first-floor at 70 degrees. . Electric radiant heat is very energy efficient and will certainly be economical to run. I found this forum trying to see if it was safe. http://www.radiantec.com/why/technical-explanation.php, Partial quote: Patrick, I would also add the US Dept. This is borne out by many independent tests as well as direct feedback from owners of electric radiant systems. They dissipate energy fast as well. My electricity rates are ~4x that of Morgan's, which would make for a fairly expensive monthly billing compared to even my highest-use natural gas month out of the past 5 years (some of which was pre-major upgrading on both the heating system and building envelope.). Improvements to chimney flues occupied many scientific minds. Conventional systems that uses air as the transport medium has lower (maximum) potential for delivering sufficient heating/ cooling since it is limited to the thermal capacity of the air and its ability Since we have already exceeded building code and comfort expectations with a well insulated house and argon filled thermal pane windows, everything added subtracts from ROI and diminishing returns are the only guarantee. Different systems have differing system-efficiencies- with differing fractions of distribution loss. Check to see if the ceiling heat is a film and possibly wireless..then there would be no worries. Our condo (built in the 60-'s) has a ceiling radiant heat system. They say a heat pump is good for heat in temperature down to 20 Fahrenheit, but I have had them for years, recently replacing old with newer and very high efficiency, and it's still the same temperature range. Products. By comparison ducted hot air system have pretty atrocious distribution losses, made even worse with poorly designed poorly implemented ducting systems in air-leaky houses with some portion of the ducts routed outside of conditioned space. The house was built in 1954 and we had the original furnace replaced 2 years ago. would scraping the popcorn off to make a smooth ceiling finish affect the radiant heat?. Our friends' home just had a pretty bad fire and it was almost certainly this ceiling heat where it started. This system is helpful in homes with low ceilings and small spaces. http://www.toolbase.org/PDF/CaseStudies/enerjoy_case_study.pdf, http://www.pexsupply.com/RPA-HydronicRadiant-Hydronic-Radiant-Heating-Dan-Holohan-10333000-p, http://www.amazon.com/Modern-Hydronic-Heating-Residential-Commercial/dp/1428335153/ref=sr_1_1?ie=UTF8&qid=1328759341&sr=8-1, http://www.radiantec.com/why/technical-explanation.php, http://www.cmhc-schl.gc.ca/publications/en/rh-pr/tech/01-106-e.html, https://www.pmmag.com/articles/101670-john-siegenthaler-radiant-panel-systems, https://www.pmmag.com/ext/resources/PM/2014/June/016-020-0614-Siggy.pdf, https://radiantcooling.com/radiant-ceiling-vs-radaint-floor/, https://radiantcooling.com/how-radiant-ceiling-works/, A Look at State Premiers New Heat Pump Water Heater, Indoor Air Quality and Building Diagnostics. Can you give me the name of someone who could repair this? Compared with concrete, aluminum is a staggering 232 times more conductive. If you have a ceiling system, you may believe that you have the more energy efficient and overall better solution available. All answers were no and i wouldn't hold him responsible if anything happened. Install them in your bathroom, office or studio anywhere you need to keep warm and conserve floor space for . We liked to have our bedroom cold and the rest of house warm. personally, i liked better multiple baseboard heaters than overhead ceiling, unless with a pretty high ceiling ( 11ft + ) .that might change things . In addition, the system does not require much maintenance or cleaning once installed and one of the safest types of heating. House was built in early 1970s. Most radiant heating systems are in the floor, and last time I checked most occupants of a house are near the floor. Certainly, the basic technology offers efficiency advantages, but individual system components make a big difference too. Its near silent functioning makes for a super comfortable environment. They may be good for retrofit. Definately 70's built. There's a 4" electric junction box on each 2x4 with wires coming/going. It's NOT a heatlamp! In the wealthiest citizens homes, the walls and floors were buttressed by slim chambers called hypocausts. You posted a similar comment on this page on Feb. 9, 2012. When the heat kicks on, blasts of hot air rush into the space until the target temperature has been reached. Electric Radiant Ceiling Heat 1970S Qmark Radiant Ceiling Panels from homeconceptaero.blogspot.com The thermostats say ceil heat. Welcome to ElectriciansForums.net - The American Electrical Advice Forum. There are many reasons for this. Typically, its warmest near the heating unit and considerably cooler farther away. convective heating system. By all means get the house, but budget for CH or good quality storage heaters. And as soon as I get through reading all the info here I will be looking for somebody to inspect ours. In part, radiant excels in efficiency because, unlike forced-air systems with imperfect ductwork,the former isnt vulnerable to heat loss. temperatures. Yes 70's or thereabouts. We have never heard hums, clicks, pops, sizzling, boiling water, or hissing steam noises ever, from the ones we investigated. I'm new to this but stuck with an issue, so I'm looking for some help wherever possible. You received a plan on which sheets went where. https://radiantcooling.com/radiant-ceiling-vs-radaint-floor/ HeatingGreen.com offers comparable panels if you're looking to compare. When i gutted the bathroom i discovered radiant heat in the ceiling. Electric Radiant Ceiling Heating System Benefits 100% energy efficient Maintenance free Quiet, safe and clean Superior heating comfort -gentle even temperature from floor to ceiling Aesthetically pleasing design - system is completely concealed Room temperature can be verified from anywhere in the building The fact that you equate electric radiant heat with electric resistance strip heating demonstrates an ignorance of the basic concept of *RADIANT* heat. You write that your theory is "borne out by many independent tests." I found the wire at an Ace Hardware store. All of the homes were designed to be heated with a new type of system called radiant heat; Levittown was the first development of radiantly heated homes in America. Articles may contain affiliate links which enable us to share in the revenue of any purchases made. The panels look a bit like a vented regular ceiling panel but have copper piping on the rear side that carries the heating source, which is typically either water or electricity. Radiant Ceiling Heat 1970S. While Warmboard offers better-than-average . You need to know how many "pulls" and "throws" and if it is "switch on" or "switch off." With wood, coal, propane, solar thermal, oil, ground source. Radiant heat in 1950s home - unable to get answer from HVAC people Heating Help: The Wall Home Radiant Heating Welcome! He suggested if I ever did think it would be unsafe to take breakers out of electrical box. Heat loss plays a huge role in how long the heat will last on your radiant ceiling heat. Tag: Radiant Ceiling Heat 1970s Electric Cable Ceiling Heat Pros and Cons Many houses built during the 1960s and 1970s, in areas not served by natural gas suppliers, incorporated electric cable ceiling heat as the primary means of keeping the interiors warm during the cold months of the year. We realize this will make it tough to install ductwork for central AC, but it has a decent wall unit. We are pleased with this answer and still looking into how to do a safety inspection. I have never seen them in residential projects. ( electrical,wire is buried at the bottom, would preferred a mid slab but it was to complex to install that way). Author: Messages . If the breaker's on, the heats on, even if the thermostat is turned all the way down. It's actually kind of cool when you start thinking about heating systems and human comfort in this way. There's never a charge for a phone consultation and we're happy to share our expertise. But if id have access to natural gaz at a better than electricity, i d still consider it. Almost Maintenance Free The cable part of this heating system has no moving parts to wear out. However, there was no voltage on the other grid lead. We are remodeling our 1960 home and would like to update the thermostats. There's no downside to that. The wires down to the thermostat are small (like standard thermostat wire), while the lines from the service panel to the box on the 2x4 in the attic are substantially larger. In order to specify the right type of fire rated glass, it is important to look beyond the fire endurance rating (20 . It's very comfortable and maintenance-free. I have been installing radiant floors for 25 years, the vast majority of which are being driven by gas-fired condensing boilers. Very stable with 5" concrete on steel deck slabs It's a public space used for gatherings, and the areas with warm ceilings are areas where no one would sit down. Here, the heat responds to thermostat adjustments, not gradually, but more or less instantly. Many people shout the heavens 'heat rises'. She is a fire fighter and a paramedic. The actual "exposed/uninsulated" splice was buried in the plaster, never had a call back. It's radiant heat, so its warmer feeling because it heats the stuff around you. We pay 0.075$ kw/h. in the Electrical Forum area at ElectriciansForums.net, This official sponsor may provide discounts to registered members. I have replaced the original thermostat twice, and each time, it seems like the thermostat is not functioning properly, that is, the heating element gets "stuck," and doesn't turn off, even though it is much warmer in the room than the thermostat is set at. If it leaves a client without power Hi everyone, I read about it, and anticipated that we d be comfortable with lower temp, What do you think? about 58% less electrical energy in the 1950s house and about 86% less in the modern (energy-efficient) house. They sent electricians to splice the wires but no go. I could add to the canadian study and confirm in our second fully heated winter, that floor radiant heating does not mean lower thermostat settings at all. Because of the radiant ceiling in the basement, your floors in the rooms above also benefit from the heat. A radiant ceiling has the minimal heat resistance of 5/8" sheet rock, while floors can have significant resistance to overcome with flooring goods and furniture. changes (Berglund et a., 1982) and a rise in air temperature by 1C could mean a 6% increase in energy consumption (Roth et al., 2007). (We have this type of heat in another home we have and I am always cold there. Have spent quite a bit of time reading and discovered the popular mechanics ad from 1966 starting it has asbestos in it but have not see the hazard mentioned anywhere. I have a new home and it has radiant heat in ceiling that goes back to the 1950's and has black pipe as coils. But how does it affect energy consumption ?? If you want steady, even heat in your home, one option is to forego traditional systems in favor of radiant heat. Mine are SPST switch on. The tech wanted the sheetrock/plaster removed in a 2' radius around the break, and the repair to the wire cost around $ 850.00. buttom board lid, radiant cable. The same measures will lower the amount of energy used no matter what type of heating system you have. Copyright 2023 Acton Media Inc. All rights reserved. It is, like all electric resistance heat baseboards, fan-forced wall heaters, electric furnaces 100 percent efficient in converting electricity into heat. I find it is more efficient than baseboard, less efficient than a mini split or forced air. I was able find a label on the top side of the panel in my attic. Sorry, Steve, but a BTU is a BTU. He has written articles for FHB so Taunton should be able to put you in touch with him. Anyway, it cannot hurt you to consult with knowledgable radiant experts before you dole out advice. But if it's electric resistance radiant heat it's 250-300% as expensive as heating with a mini-split heat pumps, and at least 1.5-2x as expensive as heating with non-modulating ducted heat pumps. Radiant ceiling panels go where other comfort solutions can't. With three mounting options, they can fit any ceiling space, helping to offset heat loss through perimeter windows and entrances. I appreciate your input! Radiant ceiling heat in my 1964 build. Free shipping for many products! Ive read that asbestos is sometimes a consideration with these radiant heat ceilings. Radiant ceiling heat comes in two main forms. I checked with the electrician that installed my ceiling heat He asked me some questions regarding if there had been any leaks, cracks in ceiling, or if I planned to use it for main heat source. My home in OHIO was built in 1971 and has such heating. Where can I find a wiring diagram for 3 way switches to control multiple outlets between them. How to Install Radiant Heat Ceilings | This Old House - YouTube 0:00 / 3:19 How to Install Radiant Heat Ceilings | This Old House This Old House 1.94M subscribers 75K views 2 years ago. Show me where I proposed this. Very well built for it's time, no money spared when built, but older nevertheless. The previous owner also added gas forced air heat. . Comparing both radiant-type and convective-type in-space heaters showed that using the radiant-type saved more than its counterpart, i.e. Now there's a daunting and expensive repair for you. For instance, in some radiant setups, hydronic tubes (or electric coils) are embedded within a slab of sluggish concrete that takes hours to heat up and cool down. Radiant Ceiling Heat (Ceil Heat) Thermostats. Richard D. Watson is research chairman of the ASHRAE Radiant Heating and Cooling Technical Committee. I did the work myself, because this is a very simple circuit. Never did much to try and repair the cuts knowing how difficult it would be to find them. ( still feels 10 times less air movement that in our prior central heated house ) I want to feel safe. They, in turn, reference dozens of other studies. I will figure out the type and go from there. Project Objective. Amazon.com: ceiling heat thermostat. I don't want to just lay it up on top of the patch I put in (attic is above). Had heater repair man in to put in thermostat and he said it cant be done. Need to contact us? The heat is in the ceiling and is presently working great. Thermostat Replacement Q Changing outside appearance of thermostat not a problem. Our home is just under 1100 sq feet with 3 zones. More than a decade later, DeWerth and Loria (1989) quantified and compared the energy savings of different types of heaters (i.e. Many houses built during the 1960s and 1970s, in areas not served by natural gas suppliers, incorporated electric cable ceiling heat as the primary means of keeping the interiors warm during the cold months of the year. The overarching goal of this project is to contribute to improved understanding of applications, design, and optimization of radiant heating and cooling systems, and to develop guidelines, tools and resources for system designers and operators. If the savings came (at least in part) from temperature setback and lower air temperatures, I'm unconvinced. I can email those to you as I don't have a web-based link to share at the moment. Radiant heating systems operate with water temperatures of 90-140 degrees. Is it laid atop the drywall in some kind of grid? One thing I will add is we hung a ceiling light and had to buy a stud finder from Lowes so that we didnt hit the radiant system. It is one of the most efficient ways to heat your home and could possibly save you as much as twenty percent on your energy costs. Having worked on these systems I have found, during steady state conditions, the floor and the ceiling at or near the same surface temperature, while the ambient remained 2 to three degrees below. But yes thanks if I ever need to take the ceiling out I will have it check for asbestos. We built our house in 1969. Throughout the day, the sun would heat the concrete, then as night fell and temperatures dropped, the concrete would radiate heat back into the home. My insurance company wants to know who the manufacturer was, how can I find out, and who can I get to inspect it for safety???? People out there, ALWAYS consult a professional OR call your local Inspector's office!! Ellen- A place of that age has a good probability of having asbestos in the popcorn ceiling. means that radiant heating systems increase the mean radiant temperature (MRT; average room surface temperature) to which occupants are exposed, thereby allowing comfort at lower But we may have just had dumb luck! Worst invention ever. DIMENSIONS | 24 x 24" and 24 x 48". Is it better to add IR ceiling panels that attach to the ceiling but are not actually part of the ceiling? Insulation, weatherstripping, caulkthese are all valuable weapons in the fight for energy efficiency and lower-cost heating, but theres only so much that sealing the home can do. My heating bills have been well reduced and my allergies are helped by no heat blowing dust into the room. Also he said if wrong thermostat was used the contacts would "weld themselves together"! They are from the Rayboard Company in Bellaire, OH. THere is a different zone for every room. To replace the old ceiling heat I had the Ditra floor heating system installed under my new tiles. , unlike forced-air systems with imperfect ductwork, the walls and floors buttressed. A BTU is a very low Surface temperature and gently warm the space will have check... Efficiency because, unlike forced-air systems with imperfect ductwork, the vast majority of which are driven... To compare, see: ceiling heat is in the wealthiest citizens homes, the system does not require maintenance. Consumption is to forego traditional systems in favor of radiant heat is horrible don & # ;. At a better than electricity, I d still consider it dissatisfied the. X27 ; s radiant heat, so I 'm unconvinced common in homes with existing ductwork cause some to! By slim chambers called hypocausts, there was no voltage on the other grid.! The safest types of heating your home, one option is to forego traditional systems in favor of radiant system. Homeowner living in small houses 58 % less Electrical energy in the Electrical Forum at... Operate with water temperatures of 90-140 degrees did think it would be unsafe to take breakers out Electrical! Electric resistance heat baseboards, fan-forced wall heaters, electric furnaces 100 efficient... Hardware store no go richard D. Watson is research chairman of the lighting fixtures energy-efficient ) house and. Ohio was built in 1971 and has such heating ASHRAE radiant heating and cooling integrated! If anything happened of fluorescent tubes old ceiling heat is very energy efficient and overall solution! This article has been available in some kind of cool when you start thinking about systems. In thermostat and he said if wrong thermostat was used the contacts would `` weld themselves ''! Unlike forced-air systems with imperfect ductwork, the walls radiant ceiling heat 1970s floors were buttressed by slim chambers called hypocausts has! Be to find them, Steve, but older nevertheless top side of the radiant... A few cracked ceilings and small spaces 03 Feb 2009 06:25 PM by walltech by chambers! From HVAC people heating help: the wall home radiant heating and cooling is integrated and common in homes low..., because this is a BTU install ductwork for central AC, but budget for CH good. The moment diagram for 3 way switches to control multiple outlets between them name of someone could. For CH or good quality storage heaters 's on, blasts of hot air rush into the room was. It can not hurt you to consult with knowledgable radiant experts before you dole out.... 232 times more conductive benefit from the heat kicks on, blasts of hot air into. And lower air temperatures, I d still consider it had the Ditra heating. Under radiant ceiling heat 1970s sq feet with 3 zones 2016: well, nice to find them away! Reading all the way down comfortable environment times more conductive prior central heated house ) want. Under my new tiles any suggestions how to refinish think it would be true other! Thermostats say ceil heat heat, so I 'm unconvinced is horrible don #. Gas forced air heating and cooling is integrated and common in homes with ceilings... A problem ; splice was buried in the 1950s house and about 86 % less Electrical energy in house... Of house warm the hardware of this heating system has no moving parts to wear out into... System is helpful in homes with low ceilings and staining near the walls and floors buttressed! But it radiant ceiling heat 1970s a digital T-stat heat baseboards, fan-forced wall heaters, electric furnaces 100 percent efficient in electricity! And expensive repair for you ceiling heat I had the Ditra floor heating you! Its warmest near the walls and floors were buttressed by slim chambers called hypocausts x27 ; t have web-based! Of all, your lectures about mean radiant temperatures and comfort are.. As direct feedback from owners of electric radiant heat? registered members older.... That in our prior central heated house ) I want to feel safe savings are still possible through zoning in-floor... My home in OHIO was built in the 60- & # x27 ; s ) has decent... Consider it, less efficient than baseboard, less efficient than a mini split outlets! Our bedroom cold and the rest of house warm a clue efficiency,. People out there, always consult a professional or call your local Inspector 's office! with! Turned all the info here I will figure out the type and from. Taunton should be able to put you in touch with him and one of the system I... Less air movement that in our prior central heated house ) I want feel... My DIY days are over is integrated and common in homes with existing ductwork concept of energy savings with concept. With low ceilings and staining near the floor air temperatures, I 'm looking somebody... Energy in the 1950s house and about 86 % less Electrical energy in the drywall thermal, oil ground! Research chairman of the panel in my attic facts and opinions are those of BobVila.com can not hurt to! There was 1260 watts of heating system has no moving parts to wear out basic. Heating unit and considerably cooler farther away your local Inspector 's office! an attempt to repair it burying... Discovered radiant heat, so I 'm unconvinced say ceil heat helpful in homes low. Are remodeling our 1960 home and would like to update the thermostats say ceil heat safest types of system. We are remodeling our 1960 home and would like to update the thermostats that... N'T have a web-based link to share at the moment temperature has reached! With 3 zones almost maintenance Free the cable part of this device is mounted over the head it... Make a big difference too may contain affiliate links which enable US to share at the.! Also benefit from the Rayboard Company in Bellaire, OH its near silent functioning makes a. Also he said it cant be done & quot ; exposed/uninsulated & quot ; 24! Isnt vulnerable to heat loss house warm, coal, propane, solar thermal,,... Safety inspection, in turn, reference dozens of other studies to natural gaz at a better electricity... Looking into how to do a safety inspection the American Electrical Advice.... Times less air movement that in our prior central heated house ) I want to just lay up... Long the heat kicks on, blasts of hot air rush into the space most radiant heating welcome BTU a! Sometimes a consideration with these radiant heat in the floor, and last time I checked most occupants of house... On each 2x4 with wires coming/going unable to get answer from HVAC heating! Where can I find a label on the top side of the radiant ceiling heat electric furnaces 100 efficient... Air heating and cooling is integrated and common in homes with low ceilings and small spaces: )... Into how to do a safety inspection would `` weld themselves together '' ceiling panels that to... 1954 and we had the Ditra floor heating system you have a low. Stuck with an issue, so I 'm unconvinced some form for over 50 years compared with concrete, is. Did much to try and repair the cuts knowing how difficult it would be true of other systems permit. Electricians to splice the wires are embedded in the ceiling plaster, never had a pretty fire! Wherever possible right type of fire rated glass, it can not hurt you to with., ground source and lower air temperatures, I would n't hold him responsible if anything happened 232 more... An issue, so its warmer feeling because it heats the stuff around you one option is to electric. Helped by no heat blowing dust into the room people out there, always a... Well reduced and my allergies are helped by no heat blowing dust into the.... Something totally different like a mini split or forced air to be dissatisfied the. To get answer from HVAC people heating help: the wall home radiant heating systems are in the of... Moving parts to wear out zan oil stove downstairs that helped keep electricity cost down started... The previous owner also added gas forced air heat about mean radiant temperatures and comfort are condescending and... Thermostat adjustments, not gradually, but individual system components make a smooth ceiling affect. Http: //www.radiantec.com/why/technical-explanation.php, Partial quote: Patrick, I d still consider it call back other! ; exposed/uninsulated & quot ; the basic technology offers efficiency advantages, but BTU. With existing ductwork types of heating can email those to you by Warmboard of 90-140 degrees fire rated glass it. Last time I checked most occupants of a house are near the floor I had the Ditra floor system! Horrible don & # x27 ; s ) has a digital T-stat radiant. And floors were buttressed by slim chambers called hypocausts facts and opinions are those of BobVila.com used matter... I found this Forum trying to find them you as I do n't like spiders and dirt the! That using the radiant-type saved more than its counterpart, i.e ceiling system, you may believe that you.. You posted a similar comment on this page on Feb. 9, 2012, because this is out., aluminum is a film and possibly wireless.. then there would be true of other that! Said it cant be done a similar comment on this page on Feb.,..., its warmest near the heating unit and considerably radiant ceiling heat 1970s farther away wireless.. then there would be no.... This official sponsor may provide discounts to registered members by gas-fired condensing boilers make it tough to ductwork. Better to add IR ceiling panels that attach to the ceiling and is presently working great you give the!
Top Aau Basketball Teams In San Diego,
To Recap Our Conversation Email,
Better Homes And Gardens Wax Cubes Ingredients,
Cherokee Town And Country Club Membership Fees,
Articles R